Skip to content

Y401 / Y402 / Y403 Wireless I/O Modules Application Guide

The Y40 series Wireless I/O Modules are industrial devices for long-distance, low-power, cable-replacement control. They use a private LoRa link and support a planning range of up to 10 km in open areas, subject to model, antenna, installation, obstructions, interference, and site conditions. No SIM card, Internet connection, or LoRaWAN gateway is required for the basic link.

SeriesArchitectureTypical Use
Y401Point-to-point (A ↔ B)Simple bidirectional control between two fixed points
Y402One-to-many (Master ↔ Slaves)One central controller driving multiple remote points
Y403Mesh network (multi-node linkage)Multi-point coordinated control with automatic relay extension

Y401 / Y402 / Y403 models support passive dry-contact and NPN open-collector DI inputs, use SPDT relay outputs, operate on 9–36 VDC, and mount on 35 mm DIN rail. Do not apply voltage directly to DI terminals.

Y401-11-LY402-11-LY403-11-L
Y401-11-L product imageY402-11-L master imageY403-11-L product image
Point-to-pointOne-to-manyMesh network

Key Features

FeatureDescription
Long-range transmissionUp to 10 km in open areas as a model-, antenna-, and site-dependent planning value*
Module power9–36 VDC; see the selected model specification for consumption
Input and outputPassive dry-contact or NPN open-collector DI; isolated SPDT relay DO
Installation35 mm DIN rail mounting
Multi-node linkageY403 nodes can automatically forward signals and extend coverage

* Confirm the selected model specification and perform a site survey before committing to a range. The wireless link is for auxiliary control and signalling, not the sole emergency-stop, personnel-safety, or hard-real-time path.

Core Application Patterns

ApplicationRecommended relationshipSuitable familyDeployment intent
Access-control signal extensionDoor, gate, or barrier contact to a remote relayY401 or Y402Replace a long contact cable between the access point and a remote controller or indicator.
Multi-point linkage alarmAny alarm input to linked alarm outputsY403Coordinate auxiliary annunciation across distributed points; retain a certified independent life-safety path.
Remote wireless equipment controlLocal switch or PLC contact to a distant load circuitY401, Y402, or Y403Drive a correctly rated relay or contactor for pumps, valves, lamps, or other field equipment.

The module relay switches an external load circuit; it does not provide load voltage. High-power or inductive loads require a suitable contactor and surge suppression.

Typical Application Case: Smart Aquaculture

Aquaculture monitoring

Project Background

A large South American white shrimp farm faced three major challenges:

  • High labor costs and low efficiency from multiple daily manual inspections across many ponds.
  • Large fluctuations in dissolved oxygen, pH, water temperature, and ammonia levels, leading to frequent stress, disease outbreaks, and high mortality.
  • Inability to detect equipment failures (aerators, pumps, valves) or environmental anomalies in time, often resulting in major losses.

YenGear Solution

  • Deployed Y403-11-L LoRa wireless linkage controllers to achieve one-button group control and multi-node linkage of aerators, water pumps, and valves across multiple ponds.
  • Used Y201-L LoRa wireless transceivers for long-range data collection.
  • Integrated water quality sensors and built a cloud platform for real-time App / PC remote monitoring and intelligent alerts.

Project Results

  • Shrimp survival rate improved significantly and mortality losses reduced.
  • Early warning for water quality abnormalities enabled timely intervention.
  • Inspection frequency dropped sharply, achieving efficient remote unmanned management.
  • Automatic linkage of aerators and pumps reduced energy consumption.

Customer feedback: "24/7 wireless monitoring and coordinated control with no blind spots—plug-and-play."

RequirementRecommended Model
Single pond, one aerator + one pumpY401-11-L (point-to-point)
One control room + multiple pondsY402-11-L or Y402-44-L (one-to-many)
Multi-pond coordinated linkageY403-11-L (mesh, with relay extension)

Other Applicable Scenarios

Scenario 1: Smart Agriculture / Greenhouses

Greenhouse control

  • Remote control of fans, water pumps, and irrigation valves.
  • Data collection for temperature, humidity, soil moisture, CO₂, etc.
  • Automatic alerts for abnormal conditions.

Value: Significantly reduces wiring, lowers deployment costs, and enables remote management via mobile phones.

Recommended models:

RequirementRecommended Model
Two zones, one-to-one controlY401-44-L (4-channel point-to-point)
One cabinet controlling multiple zonesY402-44-L (4-channel one-to-many)
Auxiliary alarm/status linkage across all zonesY403-11-L (mesh, any-trigger-all)

Scenario 2: Remote Pump Stations / Water Treatment

  • Remote start / stop control of water pumps.
  • Real-time monitoring of water level and pressure.
  • Unmanned pump house monitoring.

Value: Solves wiring difficulties in remote areas and reduces manual inspection costs.

Recommended models:

RequirementRecommended Model
Two-point pump controlY401-11-L (point-to-point)
One station + multiple pumpsY402-44-L (one-to-many)
Distributed relay extensionY403-11-L (mesh)

Scenario 3: Smart Construction Sites / Temporary Power Supply

Wireless alarm

  • Distribution box status monitoring.
  • Equipment operation and safety monitoring.
  • Integration with Y901 alarm for full-network emergency alerts.

Value: Enhances power safety on construction sites and meets smart site construction requirements.

Recommended models:

RequirementRecommended Model
Two-point safety interlockY401-11-L (point-to-point)
One site office + multiple distribution boxesY402-11-L (one-to-many)
Auxiliary alarm/status linkage across the siteY403-11-L (mesh, any-trigger-all)

Scenario 4: Livestock Farming

Smart pig farm controller

  • Monitoring of breeding environment (temperature, humidity, harmful gases).
  • Automatic control of ventilation and feeding equipment.
  • Instant alerts for abnormal conditions.

Value: Reduces nighttime inspections and enables precision farming management.

Recommended models:

RequirementRecommended Model
Two-shed environment controlY401-22-L (2-channel point-to-point)
One controller + multiple shedsY402-44-L (one-to-many)
Coordinated ventilation status/controlY403-11-L (mesh, any-trigger-all)

Scenario 5: Tunnel and Industrial Infrastructure

  • Monitoring of tunnels, pipe galleries, and underground pipelines.
  • Remote monitoring of distant base stations and signal towers.
  • Landslide and forest fire early warning.

Value: Provides long-distance wireless control and monitoring without cabling across harsh terrain.

Recommended models:

RequirementRecommended Model
Two-end tunnel controlY401-11-L (point-to-point)
One control room + multiple tunnel segmentsY402-11-L (one-to-many)
Distributed auxiliary status linkageY403-11-L (mesh, required)

Quick Selection Reference

ScenarioTopologyRecommended Series
Aquaculture multi-pond linkageMeshY403
Greenhouse zone controlOne-to-manyY402
Irrigation field valvesPoint-to-point / MeshY401 or Y403
Tunnel auxiliary status linkageMeshY403

For detailed I/O counts, relay ratings, and wiring diagrams, see the Y4xx Selection Guide or the individual product specification pages.