Y231-L LoRa Serial Radio User Manual

Product appearance for reference; interface and markings depend on the supplied version.
Before use: Verify the delivered device’s interface, connector markings and firmware with YenGear. The instructions below describe the reference hardware and firmware; customized versions may differ.
1. Before Installation
Confirm the ordered frequency band and serial interface on the device. Use a frequency-matched 50 Ω antenna and a regulated 9 to 30 V DC supply with sufficient current for transmission. Use only frequencies and transmit power permitted at the installation location. Disconnect power before wiring.
2. Connections
The following pin functions apply to the reference device. Confirm the connector and pin numbering on the delivered unit before wiring.
| Pin | Signal | Function |
|---|---|---|
| 1 | VCC | DC supply positive |
| 2 | GND | Supply ground |
| 3 | TXD / A | Serial transmit, or RS485 A on the RS485 version |
| 4 | RXD / B | Serial receive, or RS485 B on the RS485 version |
| 5 | SET | Parameter configuration enable; low enables configuration |
| 6 | CS | Module enable; low selects sleep mode |
The connector signals depend on the ordered interface. For TTL, connect TXD to the host RX and RXD to the host TX and share signal ground; the TTL logic level is 3.3 V. For RS485, connect A and B to the matching bus terminals and follow the host equipment’s grounding requirements. For RS232, connect transmit, receive and signal ground according to the equipment pinout. Verify terminal markings before applying power.
3. Configure and Test
Configuration software
Obtain the configuration software and a compatible serial adapter from YenGear support. For the reference firmware, the manufacturer lists LoRaPRO PC software; request the version matched to the delivered device. Use an adapter matching the ordered TTL, RS232 or RS485 interface. Connect its serial signals and ground to the device, and power the device from the specified supply. Do not apply the supply voltage to the serial or control pins.
- In normal operation, connect SET to GND to enter configuration mode. The reference unit’s red and blue indicators remain on. Keep CS in the working state.
- Open the configuration software and select the adapter’s COM port. The reference software shows Device Found! after it reads the device. If it does not, check the port, adapter, wiring, power and SET state.
- Choose the frequency band and channel, radio data rate, transmit power, serial settings, network ID, mode and any security settings required for the installation. Use the same radio band, channel, data rate, network ID and encryption settings on communicating devices. Match each device’s serial settings to its connected host.
- Select SET and check for a success response. Select READ to verify the saved settings. The reference software’s DEFAULT action resets parameters; use it only when you intend to replace the existing configuration.
- Release SET to return to normal operation. Configure the other units in the same way. For an initial test, select non-Mesh mode and send a short message in both directions.
The reference configuration interface uses 9600 bps, 8 data bits, no parity and 1 stop bit. The operating serial settings can be different. Confirm the firmware and settings of the delivered unit before relying on defaults. The configuration software can display the AES key; protect access to the device and configuration interface.
Mesh setup
Select Mesh mode and assign each unit a unique node ID. Choose Node for an endpoint, Router for a forwarding unit, or Node & Router for a unit serving both roles. Set compatible radio and network parameters on every unit. Check each hop on site and allow for the additional delay. Router units must remain powered to forward messages. For the reference firmware, devices with hop=0 cannot communicate with devices set to hop>0; check the hop settings across the network. Match CRC settings between communicating units.
Data flow and response time
The manufacturer’s reference manual lists 227 and 231 bytes in different sections for its Pro mode. Other compatibility modes may have lower limits. Confirm the limit for the selected mode and delivered firmware; neither value guarantees that the buffer can accept continuous input without loss. Split larger messages and leave an interval longer than the radio transmission time before sending the next part. If the serial input is faster than the radio link, or the channel stays busy while LBT is enabled, the buffer can overflow and data can be lost. Validate packet sizes, spacing and delivery with the actual firmware and traffic; do not assume that every serial write becomes one radio packet.
The radio link adds packetization and transmission delay. For request-response protocols such as Modbus RTU, allow enough response timeout for the radio rate, message size and routing. Test error handling and recovery on site.
4. Troubleshooting
- No communication: check the antenna, power, interface version, wiring, serial settings and matching radio parameters.
- Intermittent communication: check antenna placement, obstructions, interference and supply stability during transmission. Reduce the radio data rate or adjust the installation and retest.
- Mesh route unavailable: check compatible Mesh settings, unique node IDs, router power and the reachability of each hop.
Configuration commands, defaults, exact firmware behavior and accessories depend on the supplied version. Contact [email protected] for the matching configuration instructions before deployment.